Monthly Archives: March 2020

Shearer flexible rubber cable

Shearer flexible rubber cable use:
Applicable to copper-core rubber insulated rubber sheathed flexible cables with AC rated voltage Uo / U of 3.6 / 6KV and below.
Second, using characteristics:flat cable
1, coal mining machine flexible cable (UC, UCP), mobile rubber sheathed flexible cable (UY, UYP)
1) The rated voltages of Uo / U are 0.38 / 0.66KV, 0.66 / 1.14KV and 1.9 / 3.3KV, respectively.
2) The long-term allowable operating temperature of the cable conductor is 65 ° C.
3) The minimum bending radius of the cable is 6 times the cable diameter. Continue reading

YQ, YQW, YQZP universal round rubber sheathed flexible cable

YQ, YQW, YQZP universal round rubber sheathed flexible cable manufacturing basis: Purpose:
GB5013.4-1997 JB8735.2-1998This product is applicable to the connection and use conditions of household appliances, electric tools and various mobile electrical equipment under the AC rated voltage of 450 / 750V 1450 / 750v300 / 500v300 / 300V 260 ℃ 3 “W” and below: cable model:, rated voltage of,, and, the long-term allowable working temperature of the cable does not exceed.The derivative cables of type, cable manufacturer and have weather resistance and certain oil resistance, which are suitable for outdoor use or in contact with oil pollution Continue reading

mining rubber flexible cable

UG, UGF-6000V mining rubber flexible cable

Ugf-6000v mining rubber sheathed flexible cable, ug-6000v mining rubber sheathed flexible cable

2Executive standard: 3. Application: mobile power distribution equipment and mining machinery with AC rated voltage of 6kV and below; hoisting and transportation machinery, etc.

  1.   4. service characteristics: the rated voltage of the cable is 6kV;

The long-term working temperature of the cable is + 65 ℃.Anhui Tiankang (Group)Shares Co., Ltd Continue reading

rubber sheathed flexible cable

UG / UGF6000V high voltage rubber sheathed cable

Ugf-6000v mining rubber sheathed flexible cable, ug-6000v mining rubber sheathed flexible cable

  1. 2. executive standard for high voltage rubber sheathed mining cable: TL / j30-94

3Application of UGF cable: mobile power distribution equipment and mining machinery with AC rated voltage of 6kV and below; copper core rubber insulated and sheathed flexible cable for hoisting and transportation machinery. Continue reading

General rubber sheathed flexible cable

1、General rubber sheathed flexible cable features and uses this product is suitable for household appliances, electric tools and various mobile electrical equipment with AC rated voltage of 450 / 750V and below.2、 Product executive standard gb5013-1997 III. application characteristics: 1. YC type 450 / 750V, YZ type 300 / 500V; 2. Long term allowable working temperature of conductor shall not exceed 65 ℃; 3. W type cable has weather resistance and certain oil resistance, which is suitable for outdoor or oil contact occasions.4、 Basic model and name Anhui Tiankang (Group)Shares Co., Ltd Continue reading

YC, YCW general rubber sheathed flexible cable

YC, YCW general rubber sheathed flexible cable

YC, YCW general rubber sheathed flexible cable manufacturing standard:
 
GB5013.4-1997 JB8735.2-1998, the standards adopted by this product and iec245 (1994). 450 / 750V,. 65 ℃ “W”,The specification of. Is consistent with the product application: cable model this product is applicable to the long-term working temperature of the electric tools of household appliances and various mobile multi electrical equipment cables with AC rated voltage and below. It should not exceed the long-term working temperature of the cable with weather resistance and certain oil resistance.Anhui Tiankang (Group)Shares Co., Ltd It is suitable for outdoor use in oil contact

Model Name purpose
YC, YCW Heavy rubber sheathed flexible cable It is used in all kinds of mobile electrical equipment and can bear large mechanical external force

Technical performance of cable structure:   
    When the insulation resistance between cable insulation cores is converted to the temperature of 20 ℃ 35mm, it shall be:2And below50m Ω· km 50-150 mm not less than2And below30m Ω· km 185-240mm not less than2And below20m Ω· km 435mm not less than nominal section2Cables of the following specifications shall be able to withstand the bending test. After 1500 times of reciprocating bending test, the sample shall be free of current breaking, and shall be able to withstand the voltage test of ycycwc50hz 2500v5min at AC 50Hz 2000v5min.The structure and resistance of the conductive cores of the cables which shall undergo the AC voltage test Continue reading